AS S9V2B060D3VSB S9V2-VS FURNACE 60 MBTU, 97% AFUE, 2- STAGE DOWNFLOW VARIABLE SPEED ECM, 3.0 TON BLOWER, 34"H X 17-1/2"W X 28-3/4"D

Sku#:

282025

[ "Gas Fired Furnace", "Type 2-Stage, Downflow, Condensing, Direct/Non-Direct Vent", "Btu per Hour 39000 Input/38500 Output (1-Stage), 60000 Input/58200 Output (2-Stage)", "Capacity 836 to 1251 CFM at 0.1 Inch WC (Heating), 850 to 1319 CFM at 0.1 Inch WC (Cooling)", "Control Type Thermostat", "Size 17.5 Inch Width x 28.8 Inch Depth x 34 Inch Height", "Gas Inlet Size 1-5/8 Inch", "Vent Size 3 Inch Diameter", "Inclusion/Features 1/2 HP Variable Speed Direct Drive ECM Blower Motor, High Velocity Filter, Multi-Port Inshot Burner, 120 Volt Silicon Nitride Igniter Pilot Safety Device, Orifice, Variable Speed Draft Inducer, Variable Speed Direct Drive Combustion Fan", "Voltage Rating 120 Volt AC 60 Hertz 1-Phase", "Current Rating 8.9 Amp (MCA), 15 Amp (MOP), 6.4 Amp FLA (Blower), 0.77 Amp FLA (Combustion Fan)", "Nominal Air Flow Capacity 3 Ton", "AFUE Rating 97 Percent", "Fuel Type Natural/Propane Gas", "Material Baked-On Enamel Heavy Gauge Steel (Cabinet), 20 Gauge Stainless Steel (Heat Exchanger)", "Speed Rating 5000 RPM (Combustion Fan)", "Temperature Rating 35 to 65 Deg F", "Applicable Standard ETL (Canada and US), ANSI Z21.47/CSA 2.3, ASHRAE 193" ]
More Information
Additional Information [
"Voltage Rating 120 Volt AC 60 Hertz 1-Phase",
"Current Rating 8.9 Amp (MCA), 15 Amp (MOP), 6.4 Amp FLA (Blower), 0.77 Amp FLA (Combustion Fan)",
"Nominal Air Flow Capacity 3 Ton",
"AFUE Rating 97 Percent",
"Fuel Type Natural/Propane Gas",
"Material Baked-On Enamel Heavy Gauge Steel (Cabinet), 20 Gauge Stainless Steel (Heat Exchanger)",
"Speed Rating 5000 RPM (Combustion Fan)",
"Temperature Rating 35 to 65 Deg F",
"Applicable Standard ETL (Canada and US), ANSI Z21.47/CSA 2.3, ASHRAE 193"
]
Features/Benefits 97% AFUE - Meets Utility Rebates, Lowers Utility Bills Efficient Airflow Design Reduces Electrical Energy Use Lighter, Easier-To-Move and Fit into Tight Spaces Like Short Basements or Tight Closets Works Great with Larger, High Efficiency Coils No Knockouts Variable Speed Draft Inducer Motor Increased Efficiency Integrated Furnace Control - Setup/Status/Diagnostics/Digital Display, No Dip Switches, Last Six Errors Stored, Dry Contact EAC and HUM Connections, All Multi-Pin Polarized Terminals Connections, No Spade Terminals, Low Voltage Labeled Above and Below Tubular Stainless Steel Primary Heat Exchanger 29-4C Stainless Steel Secondary Heat Exchanger Stainless Steel is a More Durable, Corrosive Resistant Material than Aluminized Steel, Integrated Rail System for Easy Access, Reduces or Eliminates Need for Baffles, Vortica Blower, Designed Exclusively for the S-Series Furnace Improved Airflow Efficiency, Durable, Easy-To-Clean, 2-Piece Housing, 1-Piece Belly Band/Motor Arm Assembly, Blower Deck has Full Length Rails for Easy Removal and Replacement, Regardless of Poise 3-Way Multi-Poise (Upflow/Horizontal Left and Right) Plus Dedicated Downflow Energy Star® Rated
Category Equipment > Gas Furnaces
Brand American Standard
Model S9V2-VS
BTU Input 60
Airflow 3.0 Ton
AFUE Capacity 97%
Product Options VARIABLE SPEED, 2-STAGE
Size 34-1/2"x17-1/2"x28"
Air Flow Configuration Downflow