Heat Pump Indoor Unit; Type Single/Multi-Zone, Ductless, Split System; Voltage Rating 208/230 Volt AC; Current Rating 0.76 Amp Full Load (ECM Blower Motor); Frequency Rating 60 Hertz; Number of Phases 1; Power Rating 1080 Watt (Cooling), 1600 Watt at 47 Deg F (Heating); Cooling Capacity 14000 BTU/Hour; Temperature Control Type Thermostat; Operating Temperature 80 Deg F Dry Bulb/67 Deg F Wet Bulb (Cooling), 70 Deg F Dry Bulb/60 Deg F Wet Bulb (Heating); Installation Wall; Enclosure Finish Munsell; Size 31-7/16 Inch Width x 9-1/8 Inch Depth x 11-5/8 Inch Height; Weight 22 Pound; Approval ETL (Canada and US); Refrigerant Type R410A; Energy Efficiency Ratio 21.6 SEER, 13 EER, 10.8 HSPF; Heating Capacity 18000 BTU/Hour at 47 Deg F; Minimum Circuit Rating 1 Amp; Airflow Rating 205 to 533 CFM Dry/170 to 498 CFM Wet (Cooling), 205 to 463 CFM Dry (Heating); Applicable Standard AHRI
Refrigerant Type R410A; Energy Efficiency Ratio 21.6 SEER, 13 EER, 10.8 HSPF; Heating Capacity 18000 BTU/Hour at 47 Deg F; Minimum Circuit Rating 1 Amp; Airflow Rating 205 to 533 CFM Dry/170 to 498 CFM Wet (Cooling), 205 to 463 CFM Dry (Heating); Applicable Standard AHRI
Features/Benefits
Nano Platinum and Blue Enzyme Filters Variable Compressor Speed Inverter Technology Ozone Friendly R-410A Refrigerant Auto Change Over Between Cooling and Heating Super Quiet Technology Only 19 dB (A) High-Speed Cooling and Heating Wide Airflow up to 150 Deg Long Pipe Runs up to 100 Foot Low-Ambient Heating Refrigerant Pre-Charged Easy Installation No Ductwork Needed Energy Star® Rated